Cookie Consent by Free Privacy Policy website Skip to content

Weighing Systems KIT Cestello

Download PDF datasheet

Weighing and portable platforms for every environment, application and accuracy requirement. Wheel or axle weighing in order to check the weight and the overload of any vehicle. Portable platforms easy to move and install specially indicated to create weighing station in any place. High flexibility: weight vehicles, from the small size like cars, carts, etc.. to the big size like truck, tractors, etc… Portable units in comfortable ABS case with single or mutliple channel, in order to connect one or more load cells.

Overload protection for lifting baskets

Click on the image to enlarge

Weighing Systems KIT Cestello Weighing Systems KIT Cestello Drawing

Technical specifications

Operating temperature-20 / +70°C (4 / 158°F)
Protection levelIP 67
Power supply load cellsPower supply 24 V direct current, output 4-20 mA
Linearity0,03 % of full scale
Temperature deviation0,002 % of full scale/°C
Dimensionsjunction box 125x80x40 mm without cable gland
Cell connection40 cm
Load cells materialStainless steel
Load cells capacity750 kg
Connection cable5 m – 4 x 0,25 (shield not connected to the load cell body) – 2 cables (black and grey)

For complete and up-to-date technical specifications please refer to the datasheet you can download here

Download PDF datasheet

Load cell mounting

General guidelines for installing and mounting load cells:

  • Respect the direction in which forces are applied to the load cells
  • Do not exceed the temperature limits shown on the rating plate
  • Do not remove the labels from the cells
  • Protect cables properly with sheaths or cable ducts
  • Connect each cell to earth with a suitable cable, bridging the plates of the mounting accessories if necessary
  • Do not weld on the mechanical structure once the cells are in place
  • Avoid or minimise mechanical constraints between the fixed structure and the weighed structure, to prevent weighing errors and zero return problems
  • When vibrations or dynamic loads are present, protect the cells with anti-vibration mounts
  • Protect the cells from dust build-up with suitable covers